          KV-P16T

          Base unit, DC type, 10 Inputs and 6 Transistor (Sink) Outputs

          SPECIFICATIONS

          Select Language

          Model

          KV-P16T

          General specifications

          Environmental resistance

          Operating ambient temperature

          0 to 50°C (no freezing)*1

          Operating ambient humidity

          35 to 85%RH (no condensation)

          Ambient temperature for storage

          -20 to 70°C (no freezing)

          Withstand voltage

          1,500 VAC for 1 minute (between the power supply terminal and the I/O terminals and between all the external terminals and the case)

          Noise immunity

          1,500 Vp-p or more, pulse width: 1 µs, 50 ns (by way of a noise simulator)

          Ambient operating atmosphere

          Minimal amount of dust and corrosive gas present

          Weight

          Approx 405g

          Vibration resistance

          Intermittent vibration

          Frequency: 10 to 57 Hz

          Amplitude: 0.075 mm*2

          Frequency: 57 to 150 Hz

          Acceleration: 9.8 m/s2*2

          Continuous vibration

          Frequency: 10 to 57 Hz

          Amplitude: 0.035 mm*2

          Frequency: 57 to 150 Hz

          Acceleration: 4.9 m/s2*2

          Overvoltage category

          I

          Allowable instantaneous outage time

          Less than 2 ms

          Structure

          Panel-mount type, only the operation part of the front surface has a rating of IP65.

          Power voltage

          24 VDC ± 10%

          Internal current consumption

          220mA or less

          Environmental resistance

          Insulation resistor

          50 MΩ or more (tested with a 500 VDC megger, between the power supply terminal and the I/O terminals and between all the external terminals and the case)

          Impact resistance

          Conforms to JIS B 3502 and IEC 61131-2, 147 m/s2, operating time: 11 ms, 3 times in each of the 3 directions

          Pollution degree

          2

          Function specifications

          Data access panel

          Display power

          LCD display with 3-colour backlight

          Character size

          Full-width: 7.00 mm × 7.80 mm, half-width: 3.48 mm × 7.80 mm

          Data name display

          Negative and positive displays, blinking display, scroll display Half-width characters: fixed display: 14 characters, scroll display: 64 characters Full-width characters: fixed display: 7 characters, scroll display: 32 characters

          Data display

          Sign, up to 10 digits with decimal point

          Display device

          All devices (registered with the panel editor)

          Data change

          By way of the front panel switch

          Reset function

          By way of the RESET switch

          Key protection function

          By way of the front panel switch

          Other

          Indirect specification can be used to display messages.

          Message panel

          Display power

          LCD display with 3-colour backlight

          Character size

          Full-width: 7.00 mm × 7.80 mm, half-width: 3.48 mm × 7.80 mm

          Message view

          Negative and positive displays, blinking display, scroll display Same size half-width characters: fixed display: 14 characters, scroll display: 64 characters Same size full-width characters: fixed display: 7 characters, scroll display: 32 characters Same size vertical half-width characters: fixed display: 14 characters, scroll display: 64 characters, Same size vertical full-width characters: fixed display: 7 characters, scroll display: 32 characters ×4 half-width characters: fixed display: 7 characters, scroll display: 64 characters ×4 full-width characters: fixed display: 3 characters, scroll display: 32 characters (When same size vertical characters or ×4 characters are displayed, the second line cannot be used to display nameplates.)

          Nameplate display

          2 full-width characters (4 half-width characters) × 3 nameplates, positive display

          Function switch

          F1 to F5, 5 total (F2 to F4 have nameplate displays.)

          Other

          Indirect specification can be used to display data.

          Performance specifications

          Arithmetic control method

          Stored program method

          I/O control method

          Refresh method

          Programming language

          Ladder chart method + expansion ladder method

          Instruction type

          Basic instructions: 28 kinds, application instructions: 22 kinds, calculation instructions: 26 kinds, interrupt instructions: 4 kinds

          Minimum scan time

          140 µs

          Instruction processing speed

          Basic instruction

          0.7 µs minimum

          Application instruction

          6.4 µs minimum

          Program capacity

          4,000 steps

          Expansion unit: Maximum number of units that can be attached

          8 (excluding the QL-B1)

          KL interface

          None

          Number of inputs/outputs (the KV-P main unit, includes 16 inputs/outputs)

          16 to 2,064 (when extended to the maximum number of KL Series units), 16 to 272 (when extended to the maximum number of QL Series units), 16 to 144 (when extended to the maximum number of expansion units)

          Internal auxiliary relay

          2,560 relays, 1,000 to 1,915 and 3,000 to 17,915 (including the relays for the QL Series)

          Special auxiliary relay

          160 relays, 2,000 to 2,915

          Data memory

          2,000 words, DM0000 to DM1999

          Temporary data memory

          32 words, TM00 to TM31

          Timer/counter

          0.1 s timer: TMR (0 to 6,553.5 s) 0.01 s timer: TMH (0 to 655.35 s) 0.001 s timer: TMS (0 to 65.535 s) Addition counter C Up/down counter UDC Total: 250

          Digital trimmer

          2

          High-speed counter

          30 kHz, 2-phase high-speed counter × 2 (count from 0 to 65,535)*3

          High-speed counter comparator

          4 (2 equipped for each high-speed counter), direct output possible

          Positioning control function

          1 independent axis, 50 kHz maximum

          Memory switch

          16

          Power off holding function

          Program memory

          Flash ROM rewritable 100,000 times or more

          Data memory, counter, internal auxiliary relay, contact comment (retention devices are set by MEMSW instructions)

          120 days or more (at 25°C) through use of electric double-layer capacitors, flash ROM can be used to back up data

          Self-diagnosis function

          CPU error, RAM error

          Peripheral equipment

          Programming console KZ-P3, ladder support software KV BUILDER (version 4 or later)

          Number of contact comments

          1,000 contact comments maximum can be recorded

          *1 These are the values when installed with a vertical orientation. Refer to the instruction manual for details on all other installations.
          *2 Conforms to JIS B 3502, IEC61131-2
          Number of sweeps: 10 times respectively in the X, Y, and Z directions (80 minutes)
          *3 These can be set to 24 bits.

          • PLC/HMI User Support
          • Trade Shows and Exhibitions
          • eNews Subscribe

          Controls