Recent Searches
    Series ( results)
      Models ( results)
        Keywords

          High-accuracy Positioning Sensor

          EG series

          Select Language

          Model

          SH-302*1

          SH-303A

          SH-305

          SH-308

          SH-110

          SH-114

          SH-614A

          Type

          Standard Shielded Cylindrical

          Standard Shielded Threaded

          Standard Shielded Thin

          Shape

          ø2.8×12 Cylindrical

          ø3.8×18 Cylindrical

          ø5.4×18 Cylindrical

          ø8×18 Cylindrical

          M10×18 Threaded

          M14×18 Threaded

          14×30×4.8 Thin

          Detectable object

          Ferrous metal (see Characteristics for nonferrous metals)

          Standard target (iron, t=1 mm)

          5 x 5 mm*2

          10 x 10 mm*2

          15 x 15 mm*2

          Stable detecting range

          0 to 0.6 mm

          0 to 0.8 mm

          0 to 1 mm

          0 to 2 mm

          0 to 5 mm

          Maximum detecting distance

          1.6 mm

          2 mm

          3 mm

          5 mm

          10 mm

          Repeatability

          0.001 mm*2

          0.002 mm*2

          Hysteresis

          0.03 mm*2

          0.05 mm*2

          0.01 mm*2

          0.015 mm*2

          Temperature characteristics

          0.3%/°C*2

          0.08%/°C*2

          0.04%/°C*2

          Environmental resistance

          Enclosure rating

          IP67

          Ambient temperature

          -10 to +60 °C (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

          Weight

          Approx. 30 g

          Approx. 35 g

          Approx. 45 g

          Approx. 55 g

          Approx. 63 g

          Approx. 60 g

          *1 The SH-302 cannot be used in combination with the EG-547.
          *2 Above values obtained when the detecting distance is set at 50% of the maximum stable detecting distance.

          Model

          SH-416

          SH-422*2

          SH-430*2

          SH-440*2

          SH-290*2

          SH-809*2

          SH-816*2

          SH-822*2

          SH-108

          Type

          Standard Non-shielded Cylindrical & Threaded

          Standard Non-shielded Cylindrical

          Heat-resistant*3 Shielded Cylindrical

          Heat-resistant*3 Shielded Threaded

          Heat-resistant*3 Non-shielded Cylindrical &
          Threaded

          Oil-resistant*4 Shielded Threaded

          Shape

          ø14.5×20 Cylindrical + Threaded

          ø22×35 Cylindrical + Threaded

          ø30×45 Cylindrical + Threaded

          ø40×55 Cylindrical + Threaded

          ø90×30 Cylindrical

          ø9.4×18 Cylindrical

          M16×20 Threaded

          ø22×35 Cylindrical + Threaded

          M8×25 Threaded

          Detectable object

          Ferrous metal (see Characteristics for nonferrous metals)

          Standard target (iron, t=1 mm)

          20 x 20 mm*1

          25 x 25 mm*1

          30 x 30 mm*1

          40 x 40 mm*1

          150 x 150 mm*1

          15 x 15 mm*1

          20 x 20 mm*1

          30 x 30 mm*1

          10 x 10 mm*1

          Stable detecting range

          0 to 6 mm

          0 to 9 mm

          0 to 12 mm

          0 to 18 mm

          0 to 35 mm

          0.5 to 2 mm

          1 to 4 mm

          2 to 8 mm

          0 to 2 mm

          Maximum detecting distance

          15 mm

          22 mm

          30 mm

          40 mm

          70 mm

          3.5 mm

          Repeatability

          0.005 mm*1

          0.008 mm*1

          0.01 mm*1

          0.015 mm*1

          0.03 mm*1

          0.002 mm*1

          0.005 mm*1

          0.008 mm*1

          0.002 mm*1

          Hysteresis

          0.015 mm*1

          0.02 mm*1

          0.03 mm*1

          0.05 mm*1

          0.1 mm*1

          0.04 mm*1

          0.05 mm*1

          Temperature characteristics

          0.08%/°C*1

          0.2%/°C*1

          Environmental resistance

          Enclosure rating

          IP67

          Heat-resistant

          Oil-resistant

          Ambient temperature

          -10 to +60 °C (No freezing)

          -10 to +200 °C (No freezing)

          -10 to +60 °C (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

          Weight

          Approx. 73 g

          Approx. 195 g

          Approx. 225 g

          Approx. 280 g

          Approx. 650 g

          Approx. 55 g

          Approx. 83 g

          Approx. 170 g

          Approx. 45 g

          *1 Above values obtained when the detecting distance is set at 50% of the maximum stable detecting distance.
          *2 The EG-547(W) cannot be used in combination with SH-422, 430, 440, 290, 809, 816 and 822.
          *3 Precautions when using heat-resistant sensor head:
          Use the sensor within the stable detecting range.
          The heat-resistant sensor head is not waterproof; do not use this sensor head in a location directly exposed to liquid or steam.
          *4 Not designed for immersed use.

          Amplifier

          Model

          EG-520

          EG-530

          EG-540*3

          EG-545*3

          EG-547*4

          EG-547W*6

          Type

          DC

          AC

          AC adj-dial

          AC, tolerance setting*5

          DC, tolerance setting

          Sensitivity adjustment

          15-turn trimmer

          10-turn potentiometer dial

          10-turn potentiometer dials

          Function

          Operation mode

          N.O./N.C. (switch-selectable)

          N.O./N.C. switch-selectable
          (contact output only)

          External synchronization,
          analog voltage
          switch-selectable

          External synchronisation

          External synchronization

          Equipment (contact output only)

          Equipment (both without contacts and with contacts)

          Equipment (both without contacts and with contacts)

          Output

          Control output 1 (NPN)

          200 mA max. (40 V max.)
          Residual voltage: 1 V max.*1

          100 mA max. (40 V max.) Residual voltage: 1 V max.*1

          2 x 100 mA max.*1 (40 V max.)
          Residual voltage: 1 V max.*1

          Control output 2

          SPDT, 250 VAC, 2 A max. (resistive load)

          DPST (N.O.), 250 VAC,
          0.5 A max.
          (resistive load)

          Disconnection alarm output(NPN)

          100 mA max.
          (40 V max.) Residual
          voltage: 1 V max.

          Response time (Relay contact)

          1 ms

          10 ms

          3 ms

          OFF-delay time

          65 ms (contact output only)

          Temperature characteristics

          0.08%/°C*2

          Rating

          Power voltage

          11 to 30 VDC, Ripple (P-P) 10 % or less

          12 to 24 VDC, Ripple (P-P) 10 % or less

          110/120/220/240 VAC ±10 %, 50/60 Hz

          24 VDC ±10 %, Ripple (P-P) 10 % or less

          Power consumption

          100 mA mAx.

          5 VA mAx.

          120 mA or less

          Environmental resistance

          Ambient temperature

          0 to +50 °C

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

          Weight

          Approx. 110 g

          Approx. 75 g

          Approx. 330 g

          Approx. 350 g

          Approx. 390 g

          Approx. 250 g

          *1 NPN output can easily be converted to PNP output by connecting the optional OP-5148 PNP Output Converter.
          *2 Above values obtained when the detecting distance is set at 50% of the maximum stable detecting distance.
          *3 This product does not comply with EMC directives.
          *4 The EG-547(W) cannot be used in combination with SH-422, 430, 440, 290, 809, 816 and 822.
          *5 Please contact KEYENCE for information on products that comply with the EMC directive.
          *6 The EG-547W cannot be used in combination with SH-422, 430, 440, 290, 809, 816 and 822.

          Measurement Library

          • Trade Shows and Exhibitions
          • eNews Subscribe

          Measurement Sensors