Recent Searches
    Series ()
      Models ()
        Keywords

          Digital Fibre Optic SensorsFS-V10 series

          FS-V12

          Fibre Amplifier, Cable Type, Expansion Unit, NPN

          SPECIFICATIONS

          Select Language

          Model

          FS-V12

          Type

          1-line expansion unit

          Output

          NPN

          Light source

          Red LED

          Response time

          250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER TURBO)

          Operation mode

          LIGHT-ON/DARK-ON (switch-selectable)

          Indicator lamp

          Display indicator: Red LED
          Digital LED monitor: Seven segments, four digits, red LED
          Bar LED monitor: One orange LED and six green LEDs

          Timer function

          ON-delay: 40 ms /OFF-delay: 10 ms /Timer OFF (switch-selectable)

          Control output

          NPN open-collector 100 mA max. (24 VDC max.), Residual voltage: 1 V max.

          Protection circuit

          Reversed polarity protection, over-current protection, surge absorber

          Unit expansion

          Up to 16 expansion units can be connected (a total of 17 units).*1

          Mutual interference
          suppression

          FINE : 4, TURBO/SUPER: 8

          Rating

          Power voltage

          12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less*2

          Current consumption

          50 mA or less

          Environmental resistance

          Ambient light

          Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max.

          Ambient temperature

          -10 to +55 °C (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

          Shock resistance

          500 m/s2, 3 times in each of the X, Y, and Z directions

          Case material

          Polycarbonate

          Weight

          Approx. 45 g

          *1 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less.
          3 to 10 Units: -10 to 50°C, 11 to 16 Units: -10 to 45°C
          *2 Neither the FS-V12 nor the FS-V10 can be used as a standalone unit.

          • For Beginners Sensor Basics Understanding fundamental - Introduction Guide to Sensors

          Fibre Unit Finder

          • Fibre Unit Finder
          • Trade Shows and Exhibitions
          • eNews Subscribe

          Sensors