Recent Searches
    Series ()
      Models ()
        Keywords

          Manual-Calibration Fibreoptic SensorFS-V/T/M series (FS01)

          FS-M1P

          Fibre Amplifier, Cable Type, Main Unit, PNP

          SPECIFICATIONS

          Select Language

          Model

          FS-M1P

          Type

          Main unit

          Output

          PNP

          Light source

          Red LED

          Sensitivity adjustment/Mode selection

          8-turn trimmer (with indicator), FINE/TURBO (switch-selectable)

          Response time

          250 µs (FINE) /500 µs (TURBO)

          Operation mode

          LIGHT-ON/DARK-ON (switch-selectable)

          Indicator lamp

          Output: Red LED
          Stable operation: Green LED

          Timer function

          ON-delay: 40 ms/OFF-delay: 40 ms/Timer OFF (switch-selectable)

          Input

          Control output

          PNP open-collector 100 mA max. (40 VDC max.), Residual voltage: 1 V max.

          Stability output

          PNP open-collector 50 mA max. (40 VDC max.), Residual voltage: 1 V max.*1

          Protection circuit

          Reversed polarity protection, Overcurrent protection, Surge absorber

          Unit expansion

          Up to 16 expansion units can be connected (a total of 17 units)*2

          Mutual interference suppression

          FINE : 4, TURBO/SUPER: 8

          Rating

          Power voltage

          12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

          Current consumption

          35 mA or less

          Environmental resistance

          Ambient light

          Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max.

          Ambient temperature

          -10 to +55 °C (No freezing)*3

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

          Shock resistance

          500 m/s2, 3 times in each of the X, Y, and Z directions

          Case material

          Polycarbonate

          Accessories

          Fittings

          Weight

          Approx. 75 g

          *1 Only the FS-T1 and FS-M1 can provide stability outputs.
          *2 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less.
          3 to 10 Units: -10 to +50°C (14 to 122°F), 11 to 16 Units: -10 to +45°C (14 to 113°F)
          *3 When extended, the ambient usage temperature varies according to the following conditions. Be sure to mount units on a DIN rail (attached to a metal plate) and ensure that the output current is 20 mA or less. When extended

          • For Beginners Sensor Basics Understanding fundamental - Introduction Guide to Sensors

          Fibre Unit Finder

          • Fibre Unit Finder
          • Trade Shows and Exhibitions
          • eNews Subscribe

          Sensors