          LV-51MP

          Amplifier Unit, Main Unit, PNP

          [Discontinued model]

          This model has been discontinued.

          Recommended Replaceable Products
          To contact us:

          SPECIFICATIONS

          Select Language

          Model

          LV-51MP

          Type

          PNP output

          Main unit/Expansion unit

          Main unit

          Control output

          PNP open-collector x 2 channels, 30 VDC max., 100 mA, max. residual voltage (1.0 V max.)

          Response speed

          FINE : 80 µs , TURBO : 500 µs , SUPER : 4 ms

          Monitor output

          1 to 4 V for 1 to 4 V voltage output and FINE display 0 - 3000, load resistance 20 kΩ min.

          Number of interference
          preventive units

          FINE : No device (0) , TURBO : 2 units , SUPER : 4 units*1

          Detection mode

          Light intensity distinction / edge detection

          Protection circuit

          Reversed polarity protection, over-current protection, surge absorber

          Unit expansion

          Up to 7 additional expansion units can be installed (8 units including the main unit),

          Rating

          Power voltage

          12 to 24 VDC, Ripple (P-P) 10 % or less

          Power consumption

          1.5 W max. (125 mA max. for 12 V, 62.5 mA max. for 24 V)

          Environmental resistance

          Ambient temperature

          -10 to +55 °C (No freezing)*2

          Relative humidity

          35 to 85 % RH (No condensation)

          Material

          Main unit

          Polycarbonate

          Case

          Weight

          Approx. 120 g

          *1 To connect several units they must be mounted on a METAL DIN rail. Ensure that the output current is 20 mA max. With several units connected, the allowable ambient temperature range varies as follows : <return , >When 2 to 5 expansion units are additionally installed : -10 to +50ºC (14 to 122ºF).<return , >When 6 or 7 expansion units are additionally installed : -10 to +45ºC (14 to 113ºF).
          *2 When extended, the ambient usage temperature varies according to the following conditions. Be sure to mount units on a DIN rail (attached to a metal plate) and ensure that the output current is 20 mA or less. When extended