          SPECIFICATIONS

          Select Language

          Model

          PS-T0

          Type

          0-line connection

          Output

          NPN

          Response time

          660 µs to1.2 ms *1

          Operation mode

          LIGHT-ON/DARK-ON (switch-selectable)

          Indicator lamp

          Output indicator: Red LED, Stable operation indicator: Green LED, Calibration indicator: Yellow LED

          Timer function

          ON-delay: 40 ms, OFF-delay: 40 ms, Timer OFF (switch-selectable)

          External calibration input signal

          Control output

          *2

          Stability output

          *3

          Protection circuit

          Reverse polarity protection, Over-current protection, Surge absorber

          Multiple connections to Expansion units

          Up to 16 expansion units can be connected (a total of 17 units)

          Rating

          Power voltage

          12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

          Current consumption

          35 mA or less

          Environmental resistance

          Ambient temperature

          -10 to +55 °C (No freezing)*4

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

          Shock resistance

          500 m/s2, 3 times in each of the X, Y, and Z directions

          Case material

          Body/Cover: Polycarbonate

          Weight

          Approx. 20 g*5

          *1 The response speed varies depending on the number of units connected.
          *2 There is no control output cable for the PS-T0. Control output for the PS-T0 is sent from the FS-R0.
          *3 Power for the PS-T2 (P)/T0 is supplied through the PS-T1, FS-T1, FS-M1 or FS-R0.
          *4 When several units are connected, the ambient temperature requirement varies depending on the total number of units connected.
          When 3 to 10 units: -10 to +50 °C (14 to 122 °F)
          When 11 to 16 units: -10 to +45 °C (14 to 113 °F)
          When connecting several units, be sure to mount the units to a metallic DIN rail. Make sure that the output current does not exceed 20 mA.
          *5 The PS-T0 has no cable.

          • For Beginners Sensor Basics Understanding fundamental - Introduction Guide to Sensors
          • Trade Shows and Exhibitions
          • eNews Subscribe

          Back to top

          KEYENCE INDIA PVT. LTD. SKCL Triton Square, 1st Floor, No. C3 to C7,
          Thiru-Vi-Ka Industrial Estate, Guindy, Chennai – 600032,
          Tamil Nadu, India
          Phone: 1-800-103-0090
          E-mail: info@keyence.co.in
          Career Opportunities: KEYENCE Career Site

          Sensors