Amplifier Separate Type Photoelectric Sensor
PS-T series
Specs Amplifier Separate Type Photoelectric Sensor PS-T series
Thrubeam type sensor head: General purpose
Model |
PS-55 |
PS-55C*3 |
PS-05 |
PS-58 |
PS-52 |
PS-52C*3 |
PS-56 |
|||
Image |
|
|
|
|
|
|
|
|||
Type |
Thrubeam, General purpose, Long-detecting distance |
Thrubeam, General purpose, Free-positioning |
Thrubeam, General purpose, Cylindrical |
Thrubeam, General purpose, Thin |
||||||
Detecting distance |
TURBO |
4,000 mm*1 |
- |
600 mm*1 |
- |
|||||
FINE |
2,000 mm |
300 mm |
||||||||
Light source |
Infrared LED |
|||||||||
Smallest detectable object |
TURBO |
2.0 mm dia. opaque*2 |
- |
0.3 mm dia. opaque*2 |
- |
|||||
FINE |
1.0 mm dia. opaque*2 |
0.5 mm dia. opaque*2 |
0.3 mm dia. opaque*2 |
|||||||
Environmental resistance |
Enclosure rating |
IP64 |
IP67 |
- |
||||||
Ambient light |
Incandescent lamp: 4,000 lux max., Sunlight: 12,000 lux max. |
|||||||||
Ambient temperature |
-10 to +60 °C (No freezing) |
|||||||||
Relative humidity |
35 to 85 % RH (No condensation) |
|||||||||
Weight |
Approx. 30 g (Including cable) |
|||||||||
*1 For models with no specification, use FINE mode only. |
Thrubeam type sensor head: Teflon®-sheathed
Model |
PS-201 |
PS-201C*3 |
PS-202 |
|||
Image |
|
|
|
|||
Type |
Thrubeam, PFA-sheathed, Long-detecting distance |
Thrubeam, PFA-sheathed, Aperture-incorporated |
||||
Detecting distance |
TURBO |
4,000 mm*1 |
1,000 mm*1 |
|||
FINE |
2,000 mm |
500 mm |
||||
Light source |
Infrared LED |
|||||
Smallest detectable object |
TURBO |
1.2 mm dia. opaque*2 |
0.5 mm dia. opaque*2 |
|||
FINE |
0.8 mm dia. opaque*2 |
|||||
Environmental resistance |
Enclosure rating |
IP67 |
||||
Ambient light |
Incandescent lamp: 4,000 lux max., Sunlight: 12,000 lux max. |
|||||
Ambient temperature |
-10 to +60 °C (No freezing) |
|||||
Relative humidity |
35 to 85 % RH (No condensation) |
|||||
Weight |
Approx. 40 g (Including cable) |
|||||
*1 For models with no specification, use FINE mode only. |
Diffuse-reflective sensor head
Model |
PS-45 |
PS-46 |
PS-48 |
PS-205 |
PS-206 |
|||
Image |
|
|
|
|
|
|||
Type |
Diffuse-reflective, General purpose, Long-detecting distance |
Diffuse-reflective, General purpose, Thin |
Diffuse-reflective, General purpose, Cylindrical |
Diffuse-reflective, PFA-sheathed, Long-detecting distance |
Diffuse-reflective, PFA-sheathed, Narrow-beam |
|||
Detecting distance |
TURBO |
400 mm*1 |
- |
400 mm*1 |
- |
|||
FINE |
200 mm |
100 mm |
25 mm |
200 mm |
70 mm |
|||
Light source |
Infrared LED |
Red LED |
||||||
Detectable object |
Transparent and opaque |
|||||||
Spot diameter |
- |
6 mm dia. |
||||||
Hysterese |
15% max. |
10% max. |
20% max. |
15% max. |
||||
Environmental resistance |
Enclosure rating |
IP64 |
- |
IP67 |
||||
Ambient light |
Incandescent lamp: 4,000 lux max., Sunlight: 12,000 lux max. |
|||||||
Ambient temperature |
-10 to +60 °C (No freezing) |
|||||||
Relative humidity |
35 to 85 % RH (No condensation) |
|||||||
Weight |
Approx. 30 g (Including cable) |
Approx. 40 g (Including cable) |
Approx. 60 g (Including cable) |
|||||
*1 For models with no specification, use FINE mode only. |
Definite-reflective sensor head
Model |
PS-47 |
PS-47C*2 |
PS-49 |
PS-49C*2 |
|||
Image |
|
|
|
|
|||
Type |
Definite-reflective, General purpose, Small spot |
Definite-reflective, General purpose, Long-detecting distance |
|||||
Detecting distance |
TURBO |
- |
|||||
FINE |
10 mm (at centre) |
32 mm to 53 mm |
|||||
Light source |
Red LED |
||||||
Detectable object |
Transparent and opaque |
||||||
Smallest detectable object |
0.03 mm dia. copper wire*1 |
0.1 mm dia. copper wire*1 |
|||||
Spot diameter |
0.8 mm dia. |
1.5 mm dia. |
|||||
Hysterese |
3% max. |
6% max. |
|||||
Environmental resistance |
Ambient light |
Incandescent lamp: 4,000 lux max., Sunlight: 5,000 lux max. |
|||||
Ambient temperature |
-10 to +60 °C (No freezing) |
-10 to +50 °C (No freezing) |
|||||
Relative humidity |
35 to 85 % RH (No condensation) |
||||||
Weight |
Approx. 30 g (Including cable) |
||||||
*1 With thrubeam sensors, the smallest detectable object indicates the size of a detectable object from the maximum detecting distance. |
Amplifier
Model |
PS-T1 |
PS-T1P |
PS-T2 |
PS-T2P |
|||
Image |
|
|
|
|
|||
Type |
Main unit |
1-line connection |
|||||
Output |
NPN |
PNP |
NPN |
PNP |
|||
Response time |
500 µs |
||||||
Operation mode |
LIGHT-ON/DARK-ON (switch-selectable) |
||||||
Indicator lamp |
Output indicator: Red LED, Stable operation indicator: Green LED, Calibration indicator: Yellow LED |
||||||
Timer function |
ON-delay: 40 ms, OFF-delay: 40 ms, Timer OFF (switch-selectable) |
||||||
External calibration input signal |
Non-voltage input (contact, solid state) |
||||||
Control output |
NPN:100 mA max. (40 V max.) Residual voltage: 1 V max. |
PNP:100 mA max. (30 V max.) Residual voltage: 1 V max. |
NPN:100 mA max. (40 V max.) Residual voltage: 1 V max. |
PNP:100 mA max. (30 V max.) Residual voltage: 1 V max. |
|||
Stability output |
NPN:50 mA max. (40 V max.) Residual voltage: 1 V max. *1 |
PNP:50 mA max. (30 V max.) Residual voltage: 1 V max. *1 |
NPN:50 mA max. (40 V max.) Residual voltage: 1 V max. *3 |
PNP:50 mA max. (30 V max.) Residual voltage: 1 V max. *3 |
|||
Protection circuit |
Reverse polarity protection, Over-current protection, Surge absorber |
||||||
Multiple connections to Expansion units |
Up to 16 expansion units can be connected (a total of 17 units) |
||||||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
|||||
Current consumption |
35 mA or less |
||||||
Environmental resistance |
Ambient temperature |
-10 to +55 °C (No freezing)*2 |
|||||
Relative humidity |
35 to 85 % RH (No condensation) |
||||||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions |
||||||
Shock resistance |
500 m/s2, 3 times in each of the X, Y, and Z directions |
||||||
Case material |
Body/Cover: Polycarbonate |
||||||
Weight |
Approx. 75 g (including 2 m cable) |
Approx. 40 g (including 2 m cable) |
|||||
*1 Stability output is only provided by the PS-T1 (P). Stability output for the PS-T2 (P)/T0 is sent from the PS-T1, FS-T1, FS-M1 or FS-R0. |