          SPECIFICATIONS

          Select Language

          Model

          SJ-V156*1*2

          Ion generation method

          Corona discharge

          Structure

          Shock-proof, resistance-coupled

          Voltage application method/applied voltage

          Pulse AC method/±7,000 V

          Ion balance control method

          I.C.C. method

          Ion balance

          ±30 V*3

          Operating distance

          50 to 2,000 mm

          Control input

          NPN open collector or non-voltage contact signal

          Controloutput

          NPN type photorelay: max. 100 mA (40 V or less)

          Major functions

          Condition alarm output, ion level alarm output, alarm output
          Ion balance adjustment feature (via remote control)
          RS-485 communication

          Air purge connection port

          M5

          Air purge supplied pressure

          0.2 MPa or less

          Effective length

          1560 mm

          Total length

          1631 mm

          Effective length

          1560mm*4

          Rating

          Power voltage

          24 to 36 VDC ±10 %

          Current consumption

          250 mA (at 24 VDC)/150 mA (at 36 VDC)

          Environmental resistance

          Pollution degree

          2

          Overvoltage category

          I

          Ambient temperature

          0 to +50 °C

          Relative humidity

          35 to 85 % RH (No condensation)

          Materials

          Electrode probes

          Tungsten

          Material

          Ground electrode

          Stainless steel

          Main unit

          ABS plastic

          Weight

          Bar

          Approx 1,550 g

          *1 Silicon pin electrode types have (C) appended to the end of the model. (Separate specification, please inquire)
          *2 A 10-pin I/O cable or 10-pin to 10-pin modular cable is required to make the connection.
          The SJ-R036 requires a 6-pin to 8-pin modular cable to connect the bar and the controller. Please contact KEYENCE for information about CE compliance.
          *3 Value measured at operating distances of 50 mm (30 Hz), 600 mm (10 Hz), 1,500 mm (1 Hz); an operating ambient temperature between 0 to 50°C; an operating ambient humidity between 35 to 85%;
          and under a 0.3 m/s downflow.
          *4 Elective length indicates the static elimination rangeat 50 mm operating distance.