Recent Searches
    Series ( results)
      Models ( results)
        Keywords
          Fully Operational with Expanded Resources
          Click for the latest on how KEYENCE is continuing to support our customers with quick delivery, off-site testing, virtual demos and more.
          1. Home
          2. Products
          3. Controls
          4. HMI
          5. Touch Panel Display
          6. Models
          7. Removable Relay Terminal Block Unit

          Touch Panel DisplayVT3 series

          Removable Relay Terminal Block Unit

          VT-T1

          SPECIFICATIONS

          Select Language

          Model

          VT-T1

          General specifications

          Current consumption

          VT-T1: 50 mA or less, VT3-V6H (G) + VT-T1: 430 mA or less, VT3-Q5H (G) + VT-T1: 300 mA or less

          Structure

          Panel-mount type (Only the front part. When checking the connectors, the construction has dustproofing and splashproofing equivalent to IP65f.) and DIN-mount type

          Overvoltage category

          I

          Pollution degree

          3

          Power voltage

          24 VDC ±10%

          Noise resistance

          1,500 Vp-p or more, pulse width: 1 µs, 50 ns (by way of a noise simulator)

          Withstand voltage

          1500 VAC 1 minute (between power terminal and housing)

          Insulation resistance

          50 MΩ or more tested by 500 VDC megohmmeter (between power terminal and housing)

          Vibration resistance

          Intermittent vibration

          Frequency: 5 to 9 Hz

          Half amplitude: 3.5 mm*1

          Frequency: 9 to 150 Hz

          Acceleration: 9.8 m/s2*1

          Continuous vibration

          Frequency: 5 to 9 Hz

          Half amplitude: 1.75 mm*1

          Frequency: 9 to 150 Hz

          Acceleration: 4.9 m/s2 *1

          Ground

          Class D grounding
          (Class 3 grounding).

          Operating environment

          Minimal amount of dust and corrosive gas present

          Ambient operating temperature

          0 to +50°C

          Ambient operating humidity

          35 to 85%RH (No condensation)*2

          Ambient storage temperature

          -10 to +60°C (No freezing)

          Ambient storage humidity

          35 to 85%RH (No condensation)*2

          Weight

          Approx 410 g

          Performance specifications

          Can be used to enable and disable the emergency stop push-button switch

          A key switch can be used to enable and disable the emergency stop pushbutton switch.

          Power supply ON/OFF switching

          A key switch can be used to turn the power supply to the VT3 handy series on and off.

          Cable wiring terminal block conversion

          Cable wiring has been changed to a terminal block.

          I/O specifications

          PLC communication cable connection connector

          Applied standard

          Conforms to EIA RS-232C and RS-422

          Synchronization between the transmitter and receiver

          Start-stop, full duplex

          Communication distance

          15m (RS-232C)/500m (RS-422)*3

          Data length

          7 or 8 bits

          Parity

          Even, odd, none

          Communication speed

          1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 bps

          Ethernet connector

          Compliance

          IEEE802.3

          Transmission speed

          10 Mbps (10BASE-T),100 Mbps (100BASE-TX)

          Transmission medium

          STP or category 3 or higher UTP (10BASE-T), STP or category 5 or higher UTP (100BASE-TX)*4

          Maximum cable length

          100 m*5

          Maximum number of connectable hubs

          4 (10BASE-T),2 (100BASE-TX)

          Maximum number of connections

          PC application:*6 3,
          FTP: 4

          MegaLink (A/B/G)

          Applied standard

          RS-485

          Synchronization between the transmitter and receiver

          Start-stop, half duplex

          Communication speed

          19,200 bps, 115,200 bps, 0.5 Mbps, 1 Mbps, 2 Mbps

          Cable connection

          Multi-drop (branching is not possible)

          Maximum number of connectable units

          15

          Baud rate 19200

          Maximum extension distance: 1,000 m*5

          Baud rate 115200

          Baud rate 0.5 M

          Maximum extension distance: 500 m*5

          Baud rate 1 M

          Maximum extension distance: 200 m*5

          Baud rate 2 M

          Maximum extension distance: 100 m*5

          VT2 multi-link (A/B/G)

          Applied standard

          RS-485

          Synchronization between the transmitter and receiver

          Start-stop, half duplex

          Communication distance

          Maximum extension distance: 500 m*5

          Communication speed

          19200, 115200, 0.5M, 1M bit/s

          Baud rate 115200 or less

          Maximum extension distance: 500 m*5

          Baud rate 0.5 M

          Maximum extension distance: 100 m*5

          Baud rate 1 M

          Maximum extension distance: 50 m*5

          Multi-link (A/B/G)

          Applied standard

          RS-485

          Synchronization between the transmitter and receiver

          Start-stop, half duplex

          Communication distance

          Maximum extension distance: 500 m*5

          Communication speed

          19200, 38400, 57600, 115200 bit/s

          Emergency stop push-button switch monitor (TPAM/TPBM)

          Rated voltage

          30 VDC

          Rated current

          1 A (resistive load)

          Contact method

          1a contact

          Durability

          Mechanical

          50,000,000 times or more

          Electrical

          100,000 times or more

          Key switch monitor (TKAM/TKBM)

          Rated voltage

          30 VDC

          Rated current

          1 A (resistive load)

          Contact method

          1a contact

          Durability

          Mechanical

          20,000,000 times or more

          Electrical

          100,000 times or more

          *1 Conforms to JIS B 3502, IEC61131-2
          Number of sweeps: 10 times respectively in the X, Y, and Z directions (100 minutes)
          *2 When the ambient temperature is higher than 40°C, please use it in the condition of an absolute humidity of 85%RH at 40°C.
          *3 Maximum extension distance also includes the length of the cable between the VT3-V6H (G)/Q5H (G) and the VT-T1.
          *4 STP = shielded twisted pair cable, UTP = unshielded twisted pair cable
          *5 This also includes the length of the cable between the VT3-V6H (G)/Q5H (G) and the VT-T1.
          *6 PC application refers to VT STUDIO and DATA BUILDER.

          • PLC/HMI User Support
          • Trade Shows and Exhibitions
          • eNews Subscribe

          Back to top

          KEYENCE INDIA PVT. LTD. SKCL Triton Square, 1st Floor, No. C3 to C7,
          Thiru-Vi-Ka Industrial Estate, Guindy, Chennai – 600032,
          Tamil Nadu, India
          Phone: 1-800-103-0090
          E-mail: info@keyence.co.in
          Career Opportunities: KEYENCE Career Site

          Controls