High speed I/O unit KV-SIR32XT

KV-SIR32XT - High speed  I/O unit

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Data Sheet (PDF)

Manuals

CAD Data

360°view (3D PDF)

Software

  • CE Marking
  • UL Listing(c/us)

Specifications

Model

KV-SIR32XT*1

Type

High-speed I/O unit

External connection mode

Connector (MIL standard)*2

Input

Number of inputs

32 points

Input mode

24 VDC mode, 5 VDC mode*3 (Overvoltage protection function included*4)

Max. input voltage

24 VDC mode: 28.8 VDC, 5 VDC mode: 6.0 VDC

Rated input voltage

24 VDC mode: 24 VDC 5.1 mA, 5 VDC mode: 5 VDC 8.8 mA

Min. ON voltage

24 VDC mode: 19 V, 5 VDC mode: 3.5 V

Max. OFF current

24 VDC mode: 1.5 mA

Max. OFF voltage

5 VDC mode: 1.5 V

Common point mode

16 points/1 common point (2 terminals)*5

Input time constant

1 µs/10 µs/20 µs/100 µs/500 µs/1 ms/5 ms/10 ms/50 ms

Input impedance

24 VDC mode: 4.4 kΩ, 5 VDC mode: 350 Ω

Output

Number of outputs

32 points

Output form

MOSFET (N-ch) (with overcurrent protection function)*6

Rated load

30 VDC 0.2 A (1.6 A/1 common point)

Leak current at OFF

100 µA or less

Residual voltage at ON

0.5 VDC or less

Common point mode

16 points/1 common point (2 terminals)*5

Operating time

OFF to ON: 1 µs or less (Load: 5 mA to 200 mA)
ON to OFF: 5 µs or less (Load: 5 mA to 200 mA)

Internal current consumption

130 mA or less

Weight

Approx. 190 g

*1 For KV-8000/KV-7000 Series
*2 Connectors for connector-type I/O units are not included. MIL40-pin slender connector kit OP-51404 and MIL40-pin connector kit OP-22184 are available separately.
*3 5 VDC mode can only be used with IN100 to IN115.
*4 If an overvoltage is detected, all inputs (IN100 to IN115) in the shared commons will be turned OFF until the power is cycled or until PRG is switched to RUN.
*5 The four input and output COMs (input COM0 and COM1, and output COM2 and COM3) are independent. For each COM, those with two terminals are short-circuited internally.
*6 Even if an overcurrent is detected at only one point, protection operation (output OFF) will be enforced for all of the outputs in the shared commons (COM2: OUT200 to 215, COM3: OUT300 to 315) and automatic recovery will be repeated until the cause is eliminated.

Data Sheet (PDF) Other Models