Programmable Logic Controller
KV-8000 series
4-axis Pulse Train Positioning Motion Unit KV-MC40V
*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.
Specifications
Model | KV-MC40V | |||
Type | Positioning/Motion unit | |||
Number of control axes | 4 axes + 1 axis (virtual axis) | |||
Built-in device | Relay: 1280 points (80 ch), Data memory: 90 words (high speed) /582 words (simple) | |||
Output format | Differential line driver output (switchable among 1-pulse method, 2-pulse method, and A/B-phase method) | |||
Connectable CPU units | KV-8000/7500/7300/5500/5000/3000 | |||
Max. output pulse | 4 MHz | |||
Control mode | Position control | |||
Control period | 1.0 ms | |||
External interface | Input: Photocoupler input, Output: Open collector output (30 VDC 50 mA) | |||
Input time constant | Each input is set in 11 stages for each block | |||
Axis control function execution method | Ladder program, motion flow | |||
Motion flow | Program capacity | 768 KB | ||
Max. number of blocks | A total of 256 blocks in all flows | |||
Max. number of flows | 32 | |||
Number of simultaneous activities | Number of connectable axes × 2 | |||
Position unit | mm, deg (angle), PLS (pulse count), decimal point position from 0 to 9 digits, unit conversion function available | |||
Cumulative address | -2,147,483,648 to +2,147,483,647 instruction units | |||
Positioning control | Positioning mode | Absolute value/relative value | ||
Position setting range | -2,147,483,648 to +2,147,483,647 instruction units | |||
Interpolation | Straight-line interpolation (up to 16 axes), arc interpolation, helical interpolation | |||
Single operation address | -2,147,483,648 to +2,147,483,647 instruction units | |||
Acceleration/deceleration curve | Straight-line, SIN, Bezier | |||
Acceleration/deceleration time | 0 to 65,535 ms | |||
Start-up time | Independent: 500 to 600 µs, Interpolation (straight-line 2 axes): 600 to 700 µs, Interpolation (arc 2 axes): 700 to 800 µs, | |||
M-code | 1 to 65,000, WITH/AFTER mode | |||
Sensor positioning | External input - based switching control from speed to position | |||
Number of points | 800 points/axis | |||
Synchronisation control | Input | Counter (KV-MX1 required), instruction coordinates, current coordinates (KV-ML16V only) | ||
Clutch | Select from direct, slide, and follow-up | |||
Cam | Resolution: 2,048 to 32,768, Amount of data: 4 to 64 (Number changes according to the resolution) | |||
Contact output | 16 points (including 8 external output points) × 2 | |||
Correction during operation | Correction via auxiliary input, phase correction, and lead angle correction | |||
Fine control | Fine data work area | 8 MB | ||
Built-in ROM capacity | 512 KB | |||
Number of settings | Built-in ROM: 100, SD memory card: 1000 | |||
Data capacity of one setting | Built-in ROM: 512 KB, SD memory card: 8 MB (KV-MX1 is required) | |||
Origin return | Origin return method | Origin sensor edge/midpoint, push origin return, Dog type ("With Z phase" or "Without Z phase" can be selected), data set type, no limit switch | ||
Speed control | Speed instruction range | - | ||
Torque control | Torque instruction range | |||
JOG/inching | Inching (The number of pulses can be specified), JOG (high speed/low speed) | |||
Teaching | Current coordinate teaching and teaching from the counter current value are supported | |||
Memory data | Point parameters 800 points (each axis), synchronisation parameters (each axis), fine setting (built-in ROM: 512 KB, expandable with a SD card), | |||
High-speed counter | When KV-MX1 is connected: INC 4 ch/ABS Grey, residual Grey, binary 2 ch (switched, based on settings), Max. 6.4 MHz (2-phase, 4 multiplication) | |||
5-V power output | 5 V ±5%, Max. 100 mA (total value) | |||
Output display | Error status/Pulse output status | |||
Self-diagnosis function | Diagnosis can be made through hardware error, various parameter errors, error number, and error messages | |||
Parameter setting | Parameters can be set from KV-HPD1, “KV STUDIO,” and ladder programs | |||
Data backup | Coordinates and error/warning history backup, parameter settings backup via flash ROM, 100,000 times switching | |||
Internal current consumption | Main unit: 180 mA or less, external I/O: 130 mA or less | |||
Weight | Approx. 225 g |