Programmable Logic Controller
KV-8000 series
Data utilisation unit KV-XD02
*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.
Specifications
Model | KV-XD02 | |||
Unit specifications | Operating ambient temperature | System configuration using a KV-5000/3000 Series expansion unit: 0 to +50°C (No freezing) | ||
Operating ambient humidity | System configuration using a KV-5000/3000 Series expansion unit: 10 to 95% RH (No condensation) | |||
Storage ambient temperature | System configuration using a KV-5000/3000 Series expansion unit: −20 to +70°C | |||
Storage relative humidity | System configuration using a KV-5000/3000 Series expansion unit: 10 to 95% RH (No condensation) | |||
Power voltage | When using a power supply terminal block | System configuration using a KV-5000/3000 Series expansion unit: 24 VDC (−10%/+10%) | ||
When using the KV-PU1 | System configuration using a KV-5000/3000 Series expansion unit: 100 to 240 VAC (−15%/+10%) | |||
Common specifications | Connectable CPU unit | KV-8000 Series | ||
Max. number of connectable units | 1 | |||
Connection interface | RJ-45 8-position modular connector × 2 ports | |||
Transmission rate | 100 Mbps, 1000 Mbps *3 | |||
Transmission media | 100 Mbps: Category 5 or higher UTP or STP (STP is recommended) | |||
Maximum cable length | 100 Mbps: 100 m | |||
Maximum number of connectable hubs | 100 Mbps: 2 | |||
Internal current consumption | 500 mA or less | |||
Weight | Approx. 320 g | |||
Other general specifications | Same as CPU unit | |||
*1 Guaranteed range in which the system can be used. |