Ultra High-Speed/High-Accuracy Laser Displacement Sensor
LK-G5000 series
Controller, PNP Type, with Display Unit LK-G5000PV
*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.
Specifications
Model  | LK-G5000PV  | |||
Separate type  | LK-G5000P/LK-HD500  | |||
Type  | Single-body Main controller  | |||
Sensor head compatibility  | Available  | |||
No. of connectable sensor heads  | 2  | |||
Display  | Minimum display unit  | 0.001 µm  | ||
Display range  | ±999.999 µm to ±9999.99 mm, (7 settings selectable)  | |||
Display cycle  | 10 times/sec  | |||
Display interface  | Display port  | Either the display unit (LK-HD500) or dedicated touch panel (LK-HD1001) can be connected  | ||
LED indicator  | LASER ON  | |||
Terminal block  | Analogue output voltage  | ±10 V output, Output impedance: 100 Ω*1  | ||
Analogue current output  | 4 to 20 mA, Maximum load resistance: 350 Ω*1  | |||
No. of analogue outputs  | 2*1  | |||
TIMING 1 input  | Voltage input*2  | |||
RESET 1 input  | ||||
Auto-zero 1 input  | ||||
Laser remote input  | Non-voltage or voltage input*3*1  | |||
Alarm output  | PNP open-collector output*1  | |||
General comparator output  | ||||
Expansion connector  | TIMING input  | Voltage input*1  | ||
RESET input  | ||||
Auto-zero input  | ||||
Program switching input  | ||||
Binary selection input  | ||||
Alarm output  | PNP open-collector output*1  | |||
Comparator output  | ||||
Binary output  | ||||
RS-232C interface  | Baud rate: 9600 to 115200 bps  | |||
USB interface  | USB 2.0 Hi-Speed compliant*4  | |||
Ethernet interface  | 100BASE-TX/10BASE-T*5  | |||
EtherNet/IP™interface  | Cyclic communication (implicit messaging)  | |||
PLC-Link  | The following PLCs are supported:Mitsubishi Electric: MELSEC iQ-R Series, iQ-F Series, Q Series, L Series, FX Series  | |||
Head expansion unit connector  | Up to 10 head expansion units can be connected to one main controller  | |||
Expansion unit connector  | Either of the CC-Link unit (LK-CC100) or DeviceNet® unit (LK-DN100) can be connected  | |||
Power supply  | Power supply voltage  | 24 VDC ±10%  | ||
Maximum current consumption  | 0.6 A or less with 1 head/3.5 A or less with 12 heads  | |||
Environmental resistance  | Ambient temperature  | When one or less head expansion unit is connected: 0 to +50 °C.  | ||
Relative humidity  | 35 to 85 % RH (No condensation)  | |||
Weight  | Approx. 600 g  | |||
*1 NPN open-collector output rating: 50 mA max. (40 V max.), Residual voltage: 0.5 V max.  | ||||