          Model

          FS-M1H

          Light source

          Red LED

          Sensitivity adjustment/Mode selection

          8-turn trimmer (with indicator),
          FINE/TURBO (switch-selectable)

          Response time

          20 µs (FINE) /50 µs (TURBO)

          Operation mode

          LIGHT-ON/DARK-ON (switch-selectable)

          Indicator lamp

          Output: Red LED
          Stable operation: Green LED

          Timer function

          ON-delay: 40 ms/OFF-delay: 40 ms/Timer OFF (switch-selectable)

          Control output

          NPN: 100 mA (40 V) max.
          Residual voltage: 1 V max.*1

          Stability output

          NPN open-collector: 50 mA max. (40 VDC max.), Residual voltage:1 V max.

          Protection circuit

          Reversed polarity protection, Overcurrent protection, Surge absorber

          Rating

          Power voltage

          12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

          Current consumption

          35 mA or less

          Environmental resistance

          Ambient light

          Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max.

          Ambient temperature

          -10 to +55 °C (No freezing)*2

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

          Shock resistance

          500 m/s2, 3 times in each of the X, Y, and Z directions

          Case material

          Polycarbonate

          Accessories

          Fittings

          Weight

          Approx. 75 g

          *1 La salida de alarma de interrupción de conexión no está disponible en ES-M2 (P).
          *2 When extended, the ambient usage temperature varies according to the following conditions. Be sure to mount units on a DIN rail (attached to a metal plate) and ensure that the output current is 20 mA or less. When extended

          • For Beginners Sensor Basics Understanding fundamental - Introduction Guide to Sensors
          • Trade Shows and Exhibitions
          • eNews Subscribe

          Back to top

          KEYENCE INDIA PVT. LTD. SKCL Triton Square, 1st Floor, No. C3 to C7,
          Thiru-Vi-Ka Industrial Estate, Guindy, Chennai – 600032,
          Tamil Nadu, India
          Phone: 1-800-103-0090
          E-mail: info@keyence.co.in
          Career Opportunities: KEYENCE Career Site

          Sensors