          SPECIFICATIONS

          Select Language

          Model

          LV-11A

          Main unit/Expansion unit

          Main unit

          Applicable model

          LV-H41/H51

          FDA (CDRH) Part 1040.10

          Class I

          Control output

          NPN open-collector x 2 channels, 40 VDC max., max. 100 mA, residual voltage (1.0 V max.)

          Response time

          LV-S31standard mode

          500 µs

          Protection circuit

          Reversed polarity protection, over-current protection, surge absorber

          Operation mode

          LIGHT-ON/DARK-ON (switch-selectable)

          Unit expansion

          Up to 7 additional expansion units can be installed (8 units including the main unit),

          External calibration input

          Input response time: 20 ms min.

          Rating

          Power voltage

          12 to 24 VDC, Ripple (P-P) 10 % or less

          Power consumption

          1.5 W max. (125 mA max. for 12 V, 62.5 mA max. for 24 V)

          Environmental resistance

          Ambient temperature

          -10 to +55 °C (No freezing)*1

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

          Material

          Main unit

          Polycarbonate

          Case

          Weight

          Approx. 120 g

          *1 To connect several units they must be mounted on a METAL DIN rail. Ensure that the output current is 20 mA max. With several units connected, the allowable ambient temperature range varies as follows: 1 to 2 units connected: -10 to +55 °C, 3 to 10 units connected: -10 to +50 °C, 11 to 16 units connected: -10 to +45 °C

          • For Beginners Sensor Basics Understanding fundamental - Introduction Guide to Sensors
          • Trade Shows and Exhibitions
          • eNews Subscribe

          Back to top

          KEYENCE INDIA PVT. LTD. SKCL Triton Square, 1st Floor, No. C3 to C7,
          Thiru-Vi-Ka Industrial Estate, Guindy, Chennai – 600032,
          Tamil Nadu, India
          Phone: 1-800-103-0090
          E-mail: info@keyence.co.in
          Career Opportunities: KEYENCE Career Site

          Sensors