Ultrasonic Displacement Sensor
UD-300 series
Specs Ultrasonic Displacement Sensor UD-300 series
Sensor head/Controller
| 
         Model  | 
        
         UD-310  | 
        
         UD-320  | 
        
         UD-330  | 
        
         UD-360  | 
    |||
| 
         Image  | 
        
         
  | 
        
         
  | 
        
         
  | 
        
         
  | 
    |||
| 
         Type  | 
        
         High-precision type sensor head  | 
        
         Long-range type sensor head  | 
        
         High-precision long-range type sensor head  | 
        
         Ultra long-range type sensor head  | 
    |||
| 
         Amplifier unit  | 
        
         UD-300  | 
        
         UD-300SO(5171)  | 
        
         UD-300  | 
    ||||
| 
         Measurement range  | 
        
         60 to 300 mm  | 
        
         200 to 1300 mm  | 
        
         400 to 3000 mm  | 
        
         800 to 6000 mm  | 
    |||
| 
         Display resolution  | 
        
         1mm  | 
        
         1cm  | 
    |||||
| 
         Indication system (Display)  | 
        
         ±1% of F.S.*1  | 
    ||||||
| 
         Analogue current output  | 
        
         Output current  | 
        
         4 to 20mA  | 
        
         4 to 20 mA or 0 to 20 mA (Select one range.)  | 
        
         4 to 20mA  | 
    |||
| 
         Applicable load  | 
        
         0 to 500 Ω  | 
        
         0 to 500Ω  | 
        
         0 to 500 Ω  | 
    ||||
| 
         Resolution  | 
        
         0.08mA*2  | 
        
         0.0062mA*2  | 
        
         0.08mA*2  | 
    ||||
| 
         Temperature characteristics  | 
        
         0.05% of F.S./°C  | 
    ||||||
| 
         output  | 
        
         Controloutput  | 
        
         Relay output: 1c × 2, 220 VAC, 3 A (resistive load)  | 
    |||||
| 
         Alarm output  | 
        
         Relay output: 1a, 220 VAC, 3 A (resistive load)  | 
    ||||||
| 
         Hysteresis (of detecting distance)  | 
        
         1 to 240 mm variable  | 
        
         1 to 255 mm variable  | 
        
         1 to 25 mm variable  | 
    ||||
| 
         Response time  | 
        
         38 ms (at 20 Hz)  | 
        
         56 ms (at 10 Hz)  | 
        
         86 ms (when set to 3 Hz)  | 
        
         303 ms (at 3 Hz)  | 
    |||
| 
         Minimum detectable object  | 
        
         10 x 10 mm*3  | 
        
         20 x 20 mm*3  | 
        
         50 mm □*3  | 
        
         100 x 100 mm*3  | 
    |||
| 
         Rating  | 
        
         Power voltage  | 
        
         24 VDC, Ripple (P-P) 10 % or less*4  | 
    |||||
| 
         Current consumption  | 
        
         250 mA or less  | 
    ||||||
| 
         Environmental resistance  | 
        
         Enclosure rating  | 
        
         IP65  | 
    |||||
| 
         Ambient temperature  | 
        
         -25 to +70 °C  | 
    ||||||
| 
         Relative humidity  | 
        
         35 to 85 % RH (No condensation)  | 
    ||||||
| 
         Weight  | 
        
         Approx. 190 g (not including the cord)  | 
        
         Approx. 260 g (not including the cord)  | 
        
         Approx. 330 g (not including the cord)  | 
    ||||
| 
         *1 The Analogue output linearity is ±2.5% of F.S. (The F.S. is 300 mm for the UD-310, 1300 mm for the UD-320, 6000 mm for the UD-360, and 3000 mm for the UD-330.)  | 
    |||||||