Fully Operational with Expanded Resources Click for the latest on how KEYENCE is continuing to support our customers with quick delivery, off-site testing, virtual demos and more.
  1. Home
  2. Products
  3. Sensors
  4. Positioning Sensors
  5. CCD Laser Micrometer
  6. Models
  7. Sensor Head

CCD Laser MicrometerVG series

Sensor Head

VG-035

[Discontinued model]

This model has been discontinued.

Compliance with the certification standard is ensured as of the time of shipment from our company.

Recommended Replaceable Products
To contact us:

SPECIFICATIONS

Select Language

Model

VG-035

Light source

Type

Visible red semiconductor laser

Wavelength

670 nm

Measuring area

35 mm

Setting distance

0 to 300 mm

Linearity

*1

Minimumdisplayable unit

0.5 mm dia. opaque material*2

Minimum detectable object

Repeatability

*3

Monitor output

Output voltage

Impedance

Response time

Controloutput

Control

*4

Controloutput

Controloutput

Response time

Self-timing

*4

Stability output

Response time

Digital I/O

Key input

Control input

Number of CCD pixels

5000bit

Scanning time

1.3ms

Temperature
fluctuation

0.01 % of F.S./°C (F.S. = 30 mm)

Environmental resistance

Enclosure rating

IP60

Ambient light

Incandescent lamp: 1,000 lux or less, fluorescent lamp: 8,000 lux or less*5

Ambient temperature

0 to +40 °C

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Material

Die-cast aluminum

Weight

Approx. 360 g (transmitter), Approx. 320 g (receiver)

*1 Typical data obtained when the T-to-R distance was 100 mm, the receiver-to-target distance was 50 mm and a knife edge was used to interrupt the laser beam.
*2 Typical data obtained when the T-to-R distance was 100 mm and the receiver-to-target distance was 50 mm .
*3 This is a typical example when the distance between the transmitter and receiver has been set to 100 mm and a knife edge has been used to block light at a position that is 50 mm from the receiver.
F.S. = 30 mm displays the measurement accuracy range.
*4 NPN output can easily be converted into PNP output by connecting the optional OP-5148 PNP output converter.
*5 Typical data obtained when the T-to-R distance was 100 mm 3.94", the receiver-to-target distance was 50 mm 1.97" and a knife edge was used to interrupt the laser beam.