Multi-Sensor Ionizer
SJ-F700 series
Specs Multi-Sensor Ionizer SJ-F700 series
| 
         Model  | 
        
         SJ-F700  | 
    |||
| 
         Image  | 
        
         
  | 
    |||
| 
         Voltage application method  | 
        
         Variable DC  | 
    |||
| 
         Applied voltage  | 
        
         ±8200 V max.  | 
    |||
| 
         Ion balance control method  | 
        
         Multi-I.C.C  | 
    |||
| 
         Ion balance  | 
        
         When using SJ-FB01: ±1 V *1*2  | 
    |||
| 
         Static elimination time  | 
        
         Approx. 0.5 s *3*2  | 
    |||
| 
         Installation distance  | 
        
         50 mm or more  | 
    |||
| 
         Maximum air volume  | 
        
         4.8 m3/min  | 
    |||
| 
         Ozone density  | 
        
         0.005 ppm or less  | 
    |||
| 
         Saved data  | 
        
         Items  | 
        
         Date/time, Ion level, Electrostatic charge level, Air flow, Unit status,  | 
    ||
| 
         Sampling cycle  | 
        
         0.1 s  | 
    |||
| 
         Data history  | 
        
         Data saved every hour  | 
    |||
| 
         Event log  | 
        
         Saved events: Errors, Warnings, Charge level threshold exceeded, Ion balance threshold  | 
    |||
| 
         Other functions  | 
        
         Auto-clean, Sensor feedback  | 
    |||
| 
         Input  | 
        
         IN1  | 
        
         Static elimination stop input  | 
        
         Bidirectional voltage input  | 
    |
| 
         IN2  | 
        
         Clean input  | 
    |||
| 
         IN3  | 
        
         Event trigger input  | 
    |||
| 
         Output  | 
        
         Output  | 
        
         Photo MOS relay output, N.O./N.C. switchable,  | 
    ||
| 
         Number of outputs  | 
        
         3 (OUT1 to OUT3)  | 
    |||
| 
         Functions  | 
        
         Assignable functions: Static elimination status, Ion level alarm, Condition alarm, Fan rotation  | 
    |||
| 
         Ethernet  | 
        
         Standard  | 
        
         100BASE-TX  | 
    ||
| 
         Connector  | 
        
         RJ-45 8-pin connector  | 
    |||
| 
         Rating  | 
        
         Power voltage  | 
        
         24 VDC ±10% or dedicated AC adapter (OP-88766)  | 
    ||
| 
         Current consumption  | 
        
         Normal (including input/output load): 1.6 A or less  | 
    |||
| 
         Environmental resistance  | 
        
         Ambient temperature  | 
        
         0 to +40°C (0 to +45°C when using OP-88767 or OP-88768)  | 
    ||
| 
         Relative humidity  | 
        
         35 to 85% RH (no condensation)  | 
    |||
| 
         Overvoltage category  | 
        
         I  | 
    |||
| 
         Pollution degree  | 
        
         2  | 
    |||
| 
         Material  | 
        
         Case: PC / ABS*7, Front ventilation guard: SUS, Rear suction guard: SUS, Louvers: PC / ABS*7,  | 
    |||
| 
         Weight  | 
        
         Approx. 1.2 kg  | 
    |||
| 
         *1 At a distance of 300 mm with minimum air flow, straight louvers, and relative humidity of 65%  | 
    ||||
| 
         Model  | 
        
         SJ-FB01  | 
    |||
| 
         Image  | 
        
         
  | 
    |||
| 
         Ion balance measurement  | 
        
         Measurement range  | 
        
         ±50 V  | 
    ||
| 
         Measurement accuracy  | 
        
         ±0.5 V *1  | 
    |||
| 
         Minimum display unit  | 
        
         0.1 V  | 
    |||
| 
         Sampling cycle  | 
        
         0.1 s  | 
    |||
| 
         Installation distance  | 
        
         50 mm or more from SJ-F700  | 
    |||
| 
         Temperature measurement  | 
        
         Measurement range  | 
        
         0 to +50°C  | 
    ||
| 
         Measurement accuracy  | 
        
         ±2°C *2  | 
    |||
| 
         Minimum display unit  | 
        
         0.1°C  | 
    |||
| 
         Sampling cycle  | 
        
         0.5 s  | 
    |||
| 
         Humidity measurement  | 
        
         Measurement range  | 
        
         10 to 85% RH  | 
    ||
| 
         Measurement accuracy  | 
        
         ±5% RH *2  | 
    |||
| 
         Minimum display unit  | 
        
         1% RH  | 
    |||
| 
         Sampling cycle  | 
        
         0.5 s  | 
    |||
| 
         Environmental resistance  | 
        
         Ambient temperature  | 
        
         0 to +50°C  | 
    ||
| 
         Relative humidity  | 
        
         10 to 85% RH (no condensation)  | 
    |||
| 
         Material  | 
        
         Case: PBT,  | 
    |||
| 
         Weight  | 
        
         Approx. 30 g  | 
    |||
| 
         *1 At ±15 V or less; ±10% (indicated) for other ranges  | 
    ||||