Intuitive Vision System
CV-5000 series
Recommended Replaceable Products: Intuitive Vision System - CV-X series
Contact Us: 1-800-103-0090 Enquiry form
Digital Image Sensor/Controller CV-5001P
*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.
Specifications
Model  | CV-5001P  | |||
No. of pixels  | • 512 (H) × 480 (V), Approx 240,000 pixels • 640 (H) × 480 (V), Approx 310,000 pixels  | |||
Camera input  | Two colour/monochrome  | |||
Main processor for image processing  | DSP  | |||
No. of registered settings  | SD cards 1 and 2 can each hold 1000 programs (depending on the size of the SD  | |||
Number of screens that can be registered  | Maximum 1000 screens for each program (depending on SD card size),  | |||
Internal memory capacity  | SD card slot x2 (SDHC compatible)  | |||
Window  | Measurement area  | 128 locations per program  | ||
Mask area  | 4 locations per area  | |||
Colour extraction function (valid only when a colour camera is connected)  | Colour binary, colour shade, Gray, RGB average gray (Colours can be specified  | |||
Measurement  | Area measurement  | The shapes are rectangle, rotated rectangle, circle, oval, ring, arc or polygon (up to 12  | ||
Position detection  | Pattern search  | • Multiple searches possible for both pattern area and search area. The shapes are  | ||
V-search  | • Up to 256 patterns can be searched simultaneously for both pattern area and  | |||
ShapeTrax2  | • Multiple searches possible for both pattern area and search area. The  | |||
Edge position  | • Angles can be measured. The shapes are rectangle, rotated rectangle,  | |||
Trend edge position  | • Circle or straight line can be measured from the detection results  | |||
Blob (Centre of gravity)  | The shapes are rectangle, rotated rectangle, circle, oval, ring, arc or polygon (up  | |||
Inspection mode  | Edge position  | |||
Edge pitch  | ||||
Edge count  | The shapes are rectangle, rotated rectangle, circle, oval, ring, arc, polygon (up to  | |||
Edge angle  | Shape is rectangle.  | |||
Pair edge  | The shapes are rectangle, rotated rectangle, circle, oval, ring, arc, polygon (up to  | |||
Trend edge width  | Shapes are rectangle, rotated rectangle, ring and arc  | |||
Blob (characteristic quantities)  | • Labels, center of gravity, main axis angle, area, feret diameter, perimeter,  | |||
Stain detection  | • Subtract stain detection by using subtract filter  | |||
Trend edge flaw  | • The shapes are rectangle, circle, oval, ring, arc, and polygon.  | |||
Intensity inspection  | The shapes are rectangle, rotated rectangle, circle, oval, ring, arc, polygon (up to  | |||
Colour (only when a Colour camera is connected)  | • RGB and HSB measurement supported  | |||
Geometry  | • Calculation result can be reflected  | |||
OCR  | • Character recognition for max. 2 lines of 20 characters per line  | |||
Interface  | Control input  | External trigger input  | 2 points  | |
Control input  | 18 inputs  | |||
Control output  | Universal output  | 27 outputs PNP (including two FLASH outputs linked to external trigger.)  | ||
Total comparator output  | 1 output, PNP open collector, maximum 50 mA (30 V or less)  | |||
Monitor output  | SVGA 800x600 (24-bit colour 60 Hz)  | |||
Run indicator  | Power, Error LED display  | |||
RS-232C  | Numerical value output, image data (compressible) and control input/output  | |||
Ethernet  | Numerical value output, image data (compressible) and control input/output enabled.  | |||
USB  | Numerical value output, image data (compressible) and control input/output  | |||
PLC link  | Numerical value output and control input/output using the RS-232C port or  | |||
CC-Link  | By connecting the optional CC-Link unit CA-NCL10E, numerical value input/  | |||
EtherNet/IP™  | Numerical value input/output and control input/output enabled while using an  | |||
Illumination control  | By connecting the optional illumination expansion unit, LED illumination (12 V, 24  | |||
Continuous capture function  | • 1 to 32-time multi-measurement (maximum, minimum and average values)  | |||
Execution condition setting function  | Can set whether to execute the results (OK/NG) for other measurement and  | |||
Image  | Processing area setting function  | 240,000 pixels (512 (H) x  | ||
Scan mode  | Progressive/interlace selectable  | |||
Capturing start/end line setting function  | Desired capture start/end line can be set within the image capture range.  | |||
Correction  | Position adjustment  | Batch, individual (maximum 128 settings), X, Y, ±180° rotation.  | ||
Camera gain adjustment  | Sensitivity adjustment, offset, and span adjustment  | |||
White balance adjustment (valid only when a colour camera is connected)  | Manual setting using white paper  | |||
Image inversion function  | Can generate mirror images  | |||
Scaling function  | X and Y calibration setting for each camera. Conversion from measurement  | |||
Filter function  | Count  | The same type of filter can be used up to 9 times. 13 steps.  | ||
Type  | Expand, shrink, average, median, edge sharpening, edge extract X, edge extract  | |||
Display language  | Japanese/English/German/Italian/French/Traditional Chinese/Simplified Chinese  | |||
Calculation  | Numerical  | No. of settings  | 128 calculations/1 program  | |
Arithmetic operation  | +, -, x, ÷  | |||
Arithmetic function  | Square, exponential, counting fractions as one, round-off fractions, maximum, minimum, average, average within range,  | |||
Comparative operator  | <, ==, Not  | |||
Geometric calculation  | Distance between 2 points, angle of line segment, circle radius, circle center,  | |||
Coordinate conversion function.  | Coordinate system conversion, rotating matrix  | |||
Type conversion function  | Coordinate constant conversion, constant coordinate conversion,  | |||
Logical operator  | AND, OR, NOT, XOR  | |||
Sort function  | Maximum value index output, minimum value index output  | |||
System function  | Number of measurement times, measurement time, year, month, day, time, minute, second  | |||
Time axis operation function  | Previous measurement result acquisition operator  | |||
Command memory  | 1000 command memories that can be rewritten from external devices  | |||
Support  | Statistics analysis  | No. of data  | Max. 20000 data (can be saved into an SD card in a batch)  | |
Statistical items  | Maximum, minimum, average value, deviation (3σ), total status OK/NG times  | |||
Screen save (valid when monochrome  | The following number of  | |||
Programming aid  | Image Zoom  | Between 4% and 1600% during setting or operation (6% and 2500% during full  | ||
Edge derivative wave display  | Edge waveform can be graphically displayed during setting or operation, and  | |||
Profile display  | Trend edge position and gap can be graphically displayed during setting or  | |||
Stability display  | Stain detection (stain level) is displayed during setting or operation.  | |||
Cutout projection waveform display  | OCR automatic cutout waveform graphics can be displayed during setting or  | |||
Shift all windows  | Selected windows from an identical camera or an identical registered image can  | |||
Flaw level waveform  | The flaw level waveform of the trend edge tool can be displayed as a graphic in  | |||
Display template  | No. of display templates  | 10 templates/1 program (within which 4 templates are specified values),  | ||
No. of screens that can be displayed simultaneously  | Max. 5 screens can be displayed at the same time  | |||
Hold image  | Up to the past three images (NG images) can be displayed as hold images.  | |||
Screen customisation  | No. of customised screens  | 10 screens/1 program  | ||
Custom item  | Character string: Measurement value (decimal point can be specified), result,  | |||
Measurement result interlink  | • Display colour can be changed according to the result for figures and custom  | |||
Operation rewrite function  | • Upper/lower tolerance or command memory can be rewritten during operation.  | |||
Emulation function  | Built-in emulation function that can create new program data and save data on  | |||
Program file update function  | The program data used on the CV-3001 Series or CV-5001FE can be converted  | |||
Custom menu function  | Shortcut menu to a desired program screen can be created (20 menus/program).  | |||
Memory card save function (SD2 slot only)  | • Measurement value, judgment result, NG count, measurement image  | |||
Others  | Screen capture function, password function, re-test function, file management  | |||
Rating  | Power voltage  | 24 VDC ±10 %  | ||
Current consumption  | 2.2 A (2 cameras at maximum load)  | |||
Environmental resistance  | Ambient temperature  | 0 to +50 °C  | ||
Relative humidity  | 85% RH or less (no condensation)  | |||
Weight  | Approx. 1,250 g  | |||
*1 Some models also are compatible with the RS-232C, Ethernet ports in the system.  | ||||